Was This a Permit-Required CS?

Investigation report: Confined space accident on a marine vessel.

THIS accident happened in a large compartment of an Offshore Supply Vessel (OSV). Because of a lack of appropriate ventilation and a toxic atmosphere, it should have been treated as a confined space.

An OSV is a vessel that carries supplies to offshore platforms and rigs drilling for oil and gas in the oceans, such as the waters of the Gulf of Mexico. Most of the supplies are carried on the cargo deck, but drilling mud and other chemicals are carried below the cargo deck in a compartment designated as the "Bulk Mud Room." On some OSVs, this compartment may be 60 to 100 feet long.

Inside this compartment are some 10 to 20 large pressurized cylindrical tanks, measuring 15 to 18 feet in diameter and 10 to 12 feet in height, permanently installed to carry the chemicals. Hence, although the compartment is large, it is pretty well occupied by the tanks, piping, and structures, leaving just enough room for two narrow walkways.

The Bulk Mud Room is normally accessed through watertight doors located at the forward end, where the crew quarters are located, and at the after end where the engine compartment is located. The watertight doors are normally closed for safety reasons in case of hull damage and flooding. Normally, two narrow walkways are constructed inside the Bulk Mud Room, one port and one starboard, to reach the engine compartment from the crew quarters, since inside the Bulk Mud compartment normally there is not a toxic, explosive, or asphyxiating atmosphere. But, because the watertight doors are normally closed, two small blowers (one port and one starboard) are installed so the compartment receives some outside air, creating positive-pressure ventilation.

Accident Details
On the day of the accident, the mate decided to order a crewmember to spray-paint the overhead area of the Bulk Mud Room while the vessel was tied to the dock. It was known that toxic fumes would be generated by the spray painting. In an effort to remove the paint fumes, the rotation of the two small blowers was reversed, creating "negative pressure ventilation" rather than the "positive pressure ventilation" that is the preferred method of ventilation.

The worker assigned to perform the spray paint job was provided with a respirator, but without performing any fit-testing procedures for tight-fitting respirators.

To reach the overhead areas to be painted, a 6-foot aluminum type III stepladder also was provided to fit in the narrow walkway. After the accident, the ladder was found to be defective because it had several permanent deformations on the rails and the spreader and was rated light duty, with a 200-pound working load.

After some 10 minutes of spray painting--as could have been predicted--the worker collapsed from the ladder due to the toxic fumes. He fell in the bilges and sustained major injuries.

Findings and Testimony
Despite its dimensions, the Bulk Mud Room should have been considered a confined space because:

  • It has limited means of access or egress;
  • It is not designed for continuous employee occupancy; and
  • A potential hazardous atmosphere was going to be developed.

Therefore, OSHA's confined space provisions should have been applied.

The employer disagreed with the above, arguing it was not a confined space because the watertight doors located some 50 to 60 feet from the area to be painted were left open--making the Bulk Mud Room a non-confined space, according to the employer. The employer blamed the fall on the employee, contending the employee may have tried to "walk" the ladder instead of descending from the ladder and relocating it.

The employee also claimed the damage to the ladder occurred at the time of the fall. The employee, who was seriously injured, testified he had fainted because of the fumes developed by the spray-painting process. There were no witnesses.

Regarding ventilation, everyone agreed the small blowers could not extract the paint fumes; among other reasons, this was because the intake grills of the blowers were too far from the area being painted. Nevertheless, the employer contended that because the watertight doors to the engine room and crew quarters were left open, the main engine room blowers that supply outside air to the engine room were running because a generator was in service, and this would have been enough to create a draft sufficient to dissipate the paint fumes.

Discussion
The question remains: Should the Bulk Mud Room be considered a confined space despite of its dimensions and the paint operation be subject to the Permit Required Confined Space standard in accordance with 29 CFR 1910.146, promulgated by OSHA and adopted by the departments of transportation of some states, such as Code SB-99-3 of the New York State Department of Transportation?

Or, should the Bulk Mud Room be considered a naturally ventilated space when the watertight doors at the forward and after end are open?

OSHA's 1910.146 assigns the responsibility of identifying a space as a Permit Required Confined Space to the employer. This leaves the employer free to blame the cause of this accident on other possible factors, such as misuse of the ladder by the employee.

The definition of confined space should be expanded in great detail, in my opinion, in an attempt to avoid the type of dispute generated in this case.

This article originally appeared in the February 2003 issue of Occupational Health & Safety.

Product Showcase

  • Kestrel 5400 Heat Stress Tracker WBGT Monitoring for Workplace Safety

    Ensure safety with the Kestrel® 5400 Heat Stress Tracker, the go-to choice for safety professionals and endorsed by the Heat Safety & Performance Coalition. This robust, waterless WBGT meter is ideal for both indoor and outdoor environments, offering advanced monitoring and data logging essential for OSHA compliance. It features pre-programmed ACGIH guidelines and alert settings to quickly signal critical conditions. Integrated with the cloud-based Ambient Weather Network, the 5400 allows managers to view, track, and log job site conditions remotely, ensuring constant awareness of potential hazards. Its capability for real-time mobile alerts and remote data access promotes proactive safety management and workplace protection, solidifying its role as a crucial tool in industrial hygiene. 3

  • Magid® D-ROC® GPD412 21G Ultra-Thin Polyurethane Palm Coated Work Gloves

    Magid’s 21G line is more than just a 21-gauge glove, it’s a revolutionary knitting technology paired with an advanced selection of innovative fibers to create the ultimate in lightweight cut protection. The latest offering in our 21G line provides ANSI A4 cut resistance with unparalleled dexterity and extreme comfort that no other 21-gauge glove on the market can offer! 3

  • AirChek Connect Sampling Pump

    Stay connected to your sampling with the SKC AirChek® Connect Sampling Pump! With its Bluetooth connection to PC and mobile devices, you can monitor AirChek Connect pump operation without disrupting workflow. SKC designed AirChek Connect specifically for all OEHS professionals to ensure accurate, reliable flows from 5 to 5000 ml/min and extreme ease of use. AirChek Connect offers easy touch screen operation and flexibility. It is quality built to serve you and the workers you protect. Ask about special pricing and a demo at AIHA Connect Booth 1003. 3

Featured